Project Description
RAVC250
? 1 A Contact? Rated current: 250 A
? Sealed structure, no arc leaks
? Can cut off up to 1000 V DC by magnetic quenching
? Filled with reducing gas, high reliability and stable
Coil data | |
---|---|
Rated voltage | 9~36 V DC |
Starting current | 3.6 A |
Holding current | 0.13 A (12 V DC), 0.07 A (24 V DC) |
Max. voltage | 36 V DC |
Response voltage | ≤ 9 V DC |
Drop out voltage | ≥ 4.8 V DC |
Inverse over-voltage cutoff | ≤ 2 V DC |
Power saving mode | PWM |
Operating time | ≤ 30 ms |
Release time | ≤ 10 ms |
Bounce time | ≤ 5 ms |
Contact data | |
Contact configuration | 1 A |
Contact material | Cu alloy |
Max. continuous current | 250 A |
Max. switching rating | 1000 V DC, 2500 A (300 V DC), 750 KW |
Rated contact voltage | 450 V DC |
Overload cutoff | 750 V DC 350 A 100 Ops |
Inverse cutoff | -250 A 200 V DC 1000 Ops |
Capacitive load (Charging capacitor) | 500 V 500 A 10,000 Ops |
Min. load | 1 A? 12 V DC |
Short-time current | 375 A 15 min, 500 A 2 min. (≥ 75 mm2) |
Contact resistance | ≤ 0.5 mΩ (6 V DC 20 A) |
Mechanical life | 2×105 times |
Electrical life | 450 V 1×104 times |
750 V 3×103 times | |
Auxiliary contact current | 2 A 30 V DC / 3 A 125 V AC |
Min. current of auxiliary contact | 100 mA 8 V DC |
General data | |
Rated withstand voltage (Between contacts) | 2500 V AC 60 Sec. 10 mA |
Rated withstand voltage (Coil / Contact) | 4000 V AC 60 Sec. 10 mA |
Surge voltage | 5000 V AC |
Insulation resistance | 100 MΩ (500 V DC) |
Electrical clearance | > 6 mm |
Creepage distance | > 10 mm |
Vibration | Functional test, 49 m/s2 10~200 Hz, (10 μs) |
Destructive test, 49 m/s2 10~200 Hz 4 h | |
Shock | Functional test, 196 m/s2 11 ms, (10 μs) |
Destructive test, 490 m/s2 6 ms | |
Ambient temperature (Operation) | -40~85 ℃ (No condensation) |
Operating humidity | 5~85% |
Dimension L×W×H (mm) | 80.4×52.8×73 |
Weight (g) | 380 |
Model designation | Contact load | Auxiliary contact | Contact configuration | Coil voltage | Coil termination | Special code |
RAVC | 250 | -1 | 12 | D | 1 | |
RAVC: Round type | 050: 50A | Blank: Without auxiliary contact | -1: 1 A | 12: 12VDC | D: Wire lead, without fast terminal | 01~99 |
100: 100A | A: with auxiliary contact | 24: 24VDC | E: Wire lead, with fast terminal | |||
150: 150A | A: 9~36VDC | |||||
250: 250A | ||||||
350: 350A | ||||||
Product manual - High Voltage DC Relay | Version 2.0 | 11 MB |