遮天 辰东 小说,旷世神医 http://exas.com.cn Wed, 24 Oct 2018 12:54:55 +0000 en-US hourly 1 http://exas.com.cn/wp-content/uploads/2023/12/cropped-WRG1176x1176-透明-32x32.png 1CO – WRG http://exas.com.cn 32 32 RMIE-1P http://exas.com.cn/en/archives/product-items/rmie-1p-en Wed, 24 Oct 2018 12:01:29 +0000 http://exas.com.cn/?post_type=avada_portfolio&p=14429 ? 1 C/O
? Rated current: 12 A
? Transparent housing, easy to observe the status of contacts
? Optional LED indicator
? Free-wheel diode available for DC coil
? RC-circuit circuit available for AC coil
? Test buttons are separated as red AC one and blue DC one

The post RMIE-1P appeared first on WRG.

]]>

RMIE-1P

? 1 C/O
? Rated current: 12 A
? Transparent housing, easy to observe the status of contacts
? Optional LED indicator
? Free-wheel diode available for DC coil
? RC-circuit circuit available for AC coil
? Test buttons are separated as red AC one and blue DC one

Coil data ?
Rated coil voltage 12/24/48/110 V DC, 12/24/110/230 V AC
Rated voltage frequency 50/60 Hz (AC)
Coil power DC: 0.53 W, AC: 1.2 VA
Response voltage AC:≤80%, DC: ≤75%
Drop out voltage AC: ≥30%, DC: ≥10%
Operation time / Release time Less than 20 ms / less than 10 ms (without diode) or 20 ms (with diode)
Contact data ?
Contact numbers 1 C/O
Contact material Ag alloy
Rated voltage 250 V AC
Min. switching voltage 5 V DC
Max. switching voltage 250 V AC, 30 V DC
Rated current 12 A
Min. switching current 100 mA / 5 V DC
Max. inrush current
Contact resistence ≤ 50 mΩ (1 A/6 V DC)
Mechanical service life 1×107 times
Electrical Service life (AC1) 1×105 times
General data ?
Rated withstand impulse voltage (Coil / Contact) 5 kV AC / 1 min
Rated withstand impulse voltage (Between contacts) 1 kV AC / 1 min
Surge voltage 6 kV AC (1.2/50 μs)
Insulation Resistance 1,000 MΩ (500 V DC)
Vibration Malfunction 10~55 Hz (Amplitude 1.5 mm); Endurance? 10~55 Hz (Amplitude 1.5 mm)
Shock Malfunction 98 m/s2, Endurance 980 m/s2
Ambient temperature (Operation) -40~70℃
Adapted Socket SRE-1…
Model designation Number of poles Coil voltage AC/DC Test Button Build-in protective circuit Special request
RMIE -2 24 D T L -XXX
RMIE:
Narrow version relay
1: 1 C/O 06: 06 V D: DC Blank: Standard Blank: Standard Special type or custom code,
consisting of 3 digits letters combination
2: 2 C/O 12: 12 V A: AC T: With test button L: LED
3: 3 C/O 24: 24 V D: Diode
4: 4 C/O 48: 48 V RC: RC
60: 60 V LD: LED + Diode
110: 110 V LRC: LED + RC
220: 220 V
230: 230 V

The post RMIE-1P appeared first on WRG.

]]>
RB-1P http://exas.com.cn/en/archives/product-items/rb-1p-en-2 Wed, 24 Oct 2018 09:03:54 +0000 http://exas.com.cn/?post_type=avada_portfolio&p=14422 ? 1 C/O
? Rated current: 16 A
? Plastic sealed housing for IP 67 degree
? Low profile for height tight applications
? Protective module on socket is also available

The post RB-1P appeared first on WRG.

]]>

RB-1P

? 1 C/O
? Rated current: 16 A
? Plastic sealed housing for IP 67 degree
? Low profile for height tight applications
? Protective module on socket is also available

Coil data ?
Rated coil voltage 6/12/24 V DC
Rated voltage frequency
Coil power DC: 0.4 W
Response voltage ≤75% (Room temp.)
Drop out voltage ≥5% (Room temp.)
Operation time / Release time Less than 20 ms / 10 ms
Contact data ?
Contact numbers 1 C/O
Contact material Ag alloy
Rated voltage 250 V AC
Min. switching voltage 5 V DC
Max. switching voltage 277 V AC, 30 V DC
Rated current 16 A
Min. switching current 100 mA / 5 V DC
Max. inrush current
Contact resistence < 50 mΩ (1 A/6 V DC)
Mechanical service life 1×107 times
Electrical Service life (AC1) 1×105 times
General data ?
Rated withstand impulse voltage (Coil / Contact) 5 kV AC / 1 min
Rated withstand impulse voltage (Between contacts) 1 kV AC / 1 min
Surge voltage 8 kV AC (1.2/50 μs)
Insulation Resistance 1,000 MΩ (500 V DC)
Vibration Malfunction 10~55 Hz (Amplitude 1.5 mm); Endurance? 10~55 Hz (Amplitude 1.5 mm)
Shock Malfunction 98 m/s2, Endurance 980 m/s2
Ambient temperature (Operation) -40~85℃
Adapted Socket SRB-1…
Model designation Number of poles Coil voltage AC/DC Special code Special request
RB -1 24 D 3 -XXX
RB:
Protective relay
1: 1 C/O 6: 6 V D: DC 3: Special for RB 1C Special type or custom code,
consisting of 3 digits letters combination
2: 2 C/O 12: 12 V 6: Special for RB 2C
24: 24 V

The post RB-1P appeared first on WRG.

]]>
RY-1P http://exas.com.cn/en/archives/product-items/ry-1p-en Wed, 24 Oct 2018 12:54:55 +0000 http://exas.com.cn/?post_type=avada_portfolio&p=14448 ? 1 C/O
? Rated current: 6 A
? Plastic sealed housing for IP 67 degree
? Space saving with a design width of 6 mm
? Build-in LED and protective circuit on socket

The post RY-1P appeared first on WRG.

]]>

RY-1P

? 1 C/O
? Rated current: 6 A
? Plastic sealed housing for IP 67 degree
? Space saving with a design width of 6 mm
? Build-in LED and protective circuit on socket

Coil data
Rated coil voltage 12/24/48/60 DC
Rated voltage frequency
Coil power 0.217 W (48 V DC)
Response voltage ≤70% (Room temp.)
Drop out voltage ≥5% (Room temp.)
Operation time / Release time Less than 8 ms / Less than 4 ms
Contact data
Contact numbers 1 C/O
Contact material Ag alloy
Rated voltage 250 V AC
Min. switching voltage 5 V DC
Max. switching voltage 250 V AC, 30 V DC
Rated current 6 A
Min. switching current 100 mA / 5 V DC
Max. inrush current
Contact resistence < 50 mΩ (1 A/6 V DC)
Mechanical service life 1×107 times
Electrical Service life (AC1) 1×105 times
General data
Rated withstand impulse voltage (Coil / Contact) 4 kV AC / 1 min
Rated withstand impulse voltage (Between contacts) 1 kV AC / 1 min (same contact group), 1.5 kV AC / 1 min (different contact group)
Surge voltage 6 kV AC (1.2/50 μs)
Insulation Resistance 1,000 MΩ (500 V DC)
Vibration Malfunction 10~55 Hz (Amplitude 1.5 mm); Endurance? 10~55 Hz (Amplitude 1.5 mm)
Shock Malfunction 98 m/s2, Endurance 980 m/s2
Ambient temperature (Operation) -40~55℃
Adapted Socket SRY-1…
Model designation Number of poles Coil voltage AC/DC Test Button Build-in protective circuit Special request
RY -2 24 D T L -XXX
RY:
Slim relay
1: 1 C/O 06: 06 V D: DC Blank: Standard Blank: Standard Special type or custom code,
consisting of 3 digits letters combination
2: 2 C/O 12: 12 V A: AC T: With test button L: LED
3: 3 C/O 24: 24 V D: Diode
4: 4 C/O 48: 48 V RC: RC
60: 60 V LD: LED + Diode
110: 110 V LRC: LED + RC
220: 220 V
230: 230 V