古风小说,玄幻小说排行榜完本,我欲封天 耳根 小说零 http://exas.com.cn Sun, 21 Oct 2018 12:10:58 +0000 en-US hourly 1 http://exas.com.cn/wp-content/uploads/2023/12/cropped-WRG1176x1176-透明-32x32.png New Energy Relay – WRG http://exas.com.cn 32 32 RAVR020 http://exas.com.cn/en/archives/product-items/ravr020-en Sun, 21 Oct 2018 11:31:00 +0000 http://exas.com.cn/?post_type=avada_portfolio&p=14389 ? 1 A Contact
? Rated current: 20 A
? Sealed structure, no arc leaks
? Can cut off up to 1000 V DC by magnetic quenching
? Filled with reducing gas, high reliability and stable

The post RAVR020 appeared first on WRG.

]]>

RAVR020

? 1 A Contact
? Rated current: 20 A
? Sealed structure, no arc leaks
? Can cut off up to 1000 V DC by magnetic quenching
? Filled with reducing gas, high reliability and stable
Coil data
Rated voltage 12 / 24 V DC
Rated power 3.6 W
Max. voltage 16 / 32 V DC
Response voltage ≤ 9 / 18 V DC
Drop out voltage ≥ 1 / 2 V DC
Coil resistance 40 / 160 ?
Holding current 0.3 / 0.15 A
Operating time ≤ 30 ms
Release time ≤ 10 ms
Bounce time ≤ 5 ms
Contact data
Contact configuration 1 A
Contact material Cu alloy
Max. continuous current 20 A
Max. switching rating 1000 V DC, 200 A (300 V DC), 60 KW
Rated contact voltage 450 V DC
Overload cutoff 750 V DC 60 A 50 Ops
Reverse cutoff
Min. load 1 A? 12 V DC
Short-time current 30 A 15 min, 50 A 2 min. (≥ 3 mm2)
Contact resistance ≤ 10 mΩ (6 V DC 20 A)
Mechanical life 2×105 times
Electrical life 450 V 1×104 times
750 V 3×103 times
General data
Rated withstand voltage (Between contacts) 2500 V AC 60 Sec. 10 mA
Rated withstand voltage (Coil / Contact) 4000 V AC 60 Sec. 10 mA
Surge voltage 5000 V AC
Insulation resistance 100 MΩ (500 V DC)
Electrical clearance > 5 mm
Creepage distance > 5 mm
Vibration Functional test, 43 m/s2 10~200 Hz, (10 μs)
Destructive test, 43 m/s2 10~200 Hz 4 h
Shock Functional test, 196 m/s2 11 ms, (10 μs)
Destructive test, 490 m/s2 6 ms
Ambient temperature (Operation) -40~85 ℃ (No condensation)
Operating humidity 5~85%
Dimension L×W×H (mm) 78×39.2×35
Weight (g) 160
Model designation Contact load Auxiliary contact Contact configuration Coil voltage Coil termination Special code
RAVR 020 -1 12 D 1
RAVR:
Square type
020: 20A Blank: Without
auxiliary contact
-1: 1 A 12: 12VDC D: Wire lead,
without fast terminal
01~99
040: 40A 24: 24VDC E: Wire lead,
with fast terminal
100: 100A
120: 120A
150:150A
200:200A

The post RAVR020 appeared first on WRG.

]]>
RAVR040 http://exas.com.cn/en/archives/product-items/ravr040-en Sun, 21 Oct 2018 11:54:23 +0000 http://exas.com.cn/?post_type=avada_portfolio&p=14394 ? 1 A Contact
? Rated current: 40 A
? Sealed structure, no arc leaks
? Can cut off up to 1000 V DC by magnetic quenching
? Filled with reducing gas, high reliability and stable

The post RAVR040 appeared first on WRG.

]]>

RAVR040

? 1 A Contact
? Rated current: 40 A
? Sealed structure, no arc leaks
? Can cut off up to 1000 V DC by magnetic quenching
? Filled with reducing gas, high reliability and stable
Coil data
Rated voltage 12 / 24 V DC
Rated power 3 W
Max. voltage 16 / 32 V DC
Response voltage ≤ 9 / 18 V DC
Drop out voltage ≥ 1 / 2 V DC
Coil resistance 48 / 192 ?
Holding current 0.25 / 0.125 A
Operating time ≤ 30 ms
Release time ≤ 10 ms
Bounce time ≤ 5 ms
Contact data
Contact configuration 1 A
Contact material Cu alloy
Max. continuous current 40 A
Max. switching rating 1000 V DC, 400 A (300 V DC), 120 KW
Rated contact voltage 450 V DC
Overload cutoff 750 V DC 120 A 50 Ops
Reverse cutoff -40 A 200 V DC 1000 Ops
Min. load 1 A? 12 V DC
Short-time current 60 A 15 min, 100 A 2 min. (≥ 10 mm2)
Contact resistance ≤ 10 mΩ (6 V DC 20 A)
Mechanical life 2×105 times
Electrical life 450 V 1×104 times
750 V 3×103 times
General data
Rated withstand voltage (Between contacts) 2500 V AC 60 Sec. 10 mA
Rated withstand voltage (Coil / Contact) 4000 V AC 60 Sec. 10 mA
Surge voltage 5000 V AC
Insulation resistance 100 MΩ (500 V DC)
Electrical clearance > 10 mm
Creepage distance > 10 mm
Vibration Functional test, 49 m/s2 10~200 Hz, (10 μs)
Destructive test, 49 m/s2 10~200 Hz 4 h
Shock Functional test, 196 m/s2 11 ms, (10 μs)
Destructive test, 490 m/s2 6 ms
Ambient temperature (Operation) -40~85 ℃ (No condensation)
Operating humidity 5~85%
Dimension L×W×H (mm) 72×32.6×57.7
Weight (g) 180
Model designation Contact load Auxiliary contact Contact configuration Coil voltage Coil termination Special code
RAVR 040 -1 12 D 1
RAVR:
Square type
020: 20A Blank: Without
auxiliary contact
-1: 1 A 12: 12VDC D: Wire lead,
without fast terminal
01~99
040: 40A 24: 24VDC E: Wire lead,
with fast terminal
100: 100A
120: 120A
150:150A
200:200A

The post RAVR040 appeared first on WRG.

]]>
RAVR100 http://exas.com.cn/en/archives/product-items/ravr100-en Sun, 21 Oct 2018 11:58:54 +0000 http://exas.com.cn/?post_type=avada_portfolio&p=14397 ? 1 A Contact
? Rated current: 100 A
? Sealed structure, no arc leaks
? Can cut off up to 1000 V DC by magnetic quenching
? Filled with reducing gas, high reliability and stable

The post RAVR100 appeared first on WRG.

]]>

RAVR100

? 1 A Contact
? Rated current: 100 A
? Sealed structure, no arc leaks
? Can cut off up to 1000 V DC by magnetic quenching
? Filled with reducing gas, high reliability and stable
Coil data
Rated voltage 12~24 V DC
Rated power 4.5 W
Max. voltage 16~32 V DC
Response voltage ≤ 9 / 18 V DC
Drop out voltage ≥ 1 / 2 V DC
Coil resistance 32 / 128 ?
Holding current 0.375 / 0.188 A
Operating time ≤ 30 ms
Release time ≤ 10 ms
Bounce time ≤ 5 ms
Contact data
Contact configuration 1 A
Contact material Cu alloy
Max. continuous current 100 A
Max. switching rating 1000 V DC, 1000 A (300 V DC), 300 KW
Rated contact voltage 450 V DC
Overload cutoff 750 V DC 200 A 100 Ops
Reverse cutoff -100 A 200 V DC 1000 Ops
Min. load 1 A 12 V DC
Short-time current 150 A 15 min, 225 A 2 min. (≥ 35 mm2)
Contact resistance ≤ 1.5 mΩ (6 V DC 20 A)
Mechanical life 2×105 times
Electrical life 450 V 1×104 times
750 V 3×103 times
General data
Rated withstand voltage (Between contacts) 2500 V AC 60 Sec. 10 mA
Rated withstand voltage (Coil / Contact) 4000 V AC 60 Sec. 10 mA
Surge voltage 5000 V AC
Insulation resistance 100 MΩ (500 V DC)
Electrical clearance > 6 mm
Creepage distance > 10 mm
Vibration Functional test, 43 m/s2 10~200 Hz, (10 μs)
Destructive test, 43 m/s2 10~200 Hz 4 h
Shock Functional test, 196 m/s2 11 ms, (10 μs)
Destructive test, 490 m/s2 6 ms
Ambient temperature (Operation) -40~85 ℃ (No condensation)
Operating humidity 5~85%
Dimension L×W×H (mm) 77×40.4×76.2
Weight (g) 350
Model designation Contact load Auxiliary contact Contact configuration Coil voltage Coil termination Special code
RAVR 100 -1 12 D 1
RAVR:
Square type
020: 20A Blank: Without
auxiliary contact
-1: 1 A 12: 12VDC D: Wire lead,
without fast terminal
01~99
040: 40A 24: 24VDC E: Wire lead,
with fast terminal
100: 100A
120: 120A
150:150A
200:200A

The post RAVR100 appeared first on WRG.

]]>
RAVR120 http://exas.com.cn/en/archives/product-items/ravr120-en Sun, 21 Oct 2018 12:03:21 +0000 http://exas.com.cn/?post_type=avada_portfolio&p=14399 ? 1 A Contact
? Rated current: 120 A
? Sealed structure, no arc leaks
? Can cut off up to 1000 V DC by magnetic quenching
? Filled with reducing gas, high reliability and stable

The post RAVR120 appeared first on WRG.

]]>

RAVR120

? 1 A Contact
? Rated current: 120 A
? Sealed structure, no arc leaks
? Can cut off up to 1000 V DC by magnetic quenching
? Filled with reducing gas, high reliability and stable
Coil data
Rated voltage 12 / 24 V DC
Rated power 4.5 W
Max. voltage 16 / 32 V DC
Response voltage ≤ 9 / 18 V DC
Drop out voltage ≥ 1 / 2 V DC
Coil resistance 32 / 128 ?
Holding current 0.375 / 0.188 A
Operating time ≤ 30 ms
Release time ≤ 10 ms
Bounce time ≤ 5 ms
Contact data
Contact configuration 1 A
Contact material Cu alloy
Max. continuous current 120 A
Max. switching rating 1000 V DC, 1200 A (300 V DC), 360 KW
Rated contact voltage 450 V DC
Overload cutoff 750 V DC 250 A 100 Ops
Reverse cutoff -120 A 200 V DC 1000 Ops
Min. load 1 A? 12 V DC
Short-time current 180 A 15 min, 300 A 2 min. (≥ 40 mm2)
Contact resistance ≤ 1.5 mΩ (6 V DC 20 A)
Mechanical life 2×105 times
Electrical life 450 V 1×104 times
750 V 3×103 times
General data
Rated withstand voltage (Between contacts) 2500 V AC 60 Sec. 10 mA
Rated withstand voltage (Coil / Contact) 4000 V AC 60 Sec. 10 mA
Surge voltage 5000 V AC
Insulation resistance 100 MΩ (500 V DC)
Electrical clearance > 6 mm
Creepage distance > 10 mm
Vibration Functional test, 43 m/s2 10~200 Hz, (10 μs)
Destructive test, 43 m/s2 10~200 Hz 4 h
Shock Functional test, 196 m/s2 11 ms, (10 μs)
Destructive test, 490 m/s2 6 ms
Ambient temperature (Operation) -40~85 ℃ (No condensation)
Operating humidity 5~85%
Dimension L×W×H (mm) 77×40.4×76.2
Weight (g) 350
Model designation Contact load Auxiliary contact Contact configuration Coil voltage Coil termination Special code
RAVR 120 -1 12 D 1
RAVR:
Square type
020: 20A Blank: Without
auxiliary contact
-1: 1 A 12: 12VDC D: Wire lead,
without fast terminal
01~99
040: 40A 24: 24VDC E: Wire lead,
with fast terminal
100: 100A
120: 120A
150:150A
200:200A

The post RAVR120 appeared first on WRG.

]]>
RAVR150 http://exas.com.cn/en/archives/product-items/ravr150-en Sun, 21 Oct 2018 12:07:59 +0000 http://exas.com.cn/?post_type=avada_portfolio&p=14401 ? 1 A Contact
? Rated current: 150 A
? Sealed structure, no arc leaks
? Can cut off up to 1000 V DC by magnetic quenching
? Filled with reducing gas, high reliability and stable

The post RAVR150 appeared first on WRG.

]]>

RAVR150

? 1 A Contact
? Rated current: 150 A
? Sealed structure, no arc leaks
? Can cut off up to 1000 V DC by magnetic quenching
? Filled with reducing gas, high reliability and stable
Coil data
Rated voltage 12 / 24 V DC
Rated power 6 W
Max. voltage 16 / 32 V DC
Response voltage ≤ 9 / 18 V DC
Drop out voltage ≥ 1 / 2 V DC
Coil resistance 24 / 96 ?
Holding current 0.5 / 0.25 A
Operating time ≤ 30 ms
Release time ≤ 10 ms
Bounce time ≤ 5 ms
Contact data
Contact configuration 1 A
Contact material Cu alloy
Max. continuous current 150 A
Max. switching rating 1000 V DC, 1500 A (300 V DC), 450 KW
Rated contact voltage 450 V DC
Overload cutoff 750 V DC 300 A 100 Ops
Reverse cutoff -150 A 200 V DC 1000 Ops
Min. load 1 A? 12 V DC
Short-time current 225 A 15 min, 320 A 2 min. (≥ 50 mm2)
Contact resistance ≤ 0.4 mΩ (6 V DC 20 A)
Mechanical life 2×105 times
Electrical life 450 V 1×104 times
750 V 3×103 times
General data
Rated withstand voltage (Between contacts) 2500 V AC 60 Sec. 10 mA
Rated withstand voltage (Coil / Contact) 2500 V AC 60 Sec. 10 mA
Surge voltage 5000 V AC
Insulation resistance 100 MΩ (500 V DC)
Electrical clearance > 6 mm
Creepage distance > 10 mm
Vibration Functional test, 49 m/s2 10~200 Hz, (10 μs)
Destructive test, 49 m/s2 10~200 Hz 4 h
Shock Functional test, 196 m/s2 11 ms, (10 μs)
Destructive test, 490 m/s2 6 ms
Ambient temperature (Operation) -40~85 ℃ (No condensation)
Operating humidity 5~85%
Dimension L×W×H (mm) 79×41.1×84.3
Weight (g) 400
Model designation Contact load Auxiliary contact Contact configuration Coil voltage Coil termination Special code
RAVR 150 -1 12 D 1
RAVR:
Square type
020: 20A Blank: Without
auxiliary contact
-1: 1 A 12: 12VDC D: Wire lead,
without fast terminal
01~99
040: 40A 24: 24VDC E: Wire lead,
with fast terminal
100: 100A
120: 120A
150:150A
200:200A

The post RAVR150 appeared first on WRG.

]]>
RAVR200 http://exas.com.cn/en/archives/product-items/ravr200-en Sun, 21 Oct 2018 12:10:58 +0000 http://exas.com.cn/?post_type=avada_portfolio&p=14403 ? 1 A Contact
? Rated current: 200 A
? Sealed structure, no arc leaks
? Can cut off up to 1000 V DC by magnetic quenching
? Filled with reducing gas, high reliability and stable

The post RAVR200 appeared first on WRG.

]]>

RAVR200

? 1 A Contact
? Rated current: 200 A
? Sealed structure, no arc leaks
? Can cut off up to 1000 V DC by magnetic quenching
? Filled with reducing gas, high reliability and stable
Coil data
Rated voltage 12 / 24 V DC
Rated power 34 W (0.1s) @ response, 4 W at holding
Max. voltage 16 / 32 V DC
Response voltage ≤ 9 / 18 V DC
Drop out voltage ≥ 1 / 2 V DC
Coil resistance 3 A / 1.5 A
Holding current 0.35 / 0.175 A
Operating time ≤ 30 ms
Release time ≤ 10 ms
Bounce time ≤ 5 ms
Contact data
Contact configuration 1 A
Contact material Cu alloy
Max. continuous current 200 A
Max. switching rating 1000 V DC, 2000 A (300 V DC), 600 KW
Rated contact voltage 450 V DC
Overload cutoff 750 V DC 400 A 100 Ops
Reverse cutoff -200 A 200 V DC 1000 Ops
Min. load 1 A? 12 V DC
Short-time current 300 A 15 min, 500 A 2 min. (≥ 60 mm2)
Contact resistance ≤ 0.3 mΩ (6 V DC 20 A)
Mechanical life 2×105 times
Electrical life 450 V 1×104 times
750 V 3×103 times
General data
Rated withstand voltage (Between contacts) 2500 V AC 60 Sec. 10 mA
Rated withstand voltage (Coil / Contact) 4000 V AC 60 Sec. 10 mA
Surge voltage 5000 V AC
Insulation resistance 100 MΩ (500 V DC)
Electrical clearance > 6 mm
Creepage distance > 10 mm
Vibration Functional test, 49 m/s2 10~200 Hz, (10 μs)
Destructive test, 49 m/s2 10~200 Hz 4 h
Shock Functional test, 196 m/s2 11 ms, (10 μs)
Destructive test, 490 m/s2 6 ms
Ambient temperature (Operation) -40~85 ℃ (No condensation)
Operating humidity 5~85%
Dimension L×W×H (mm) 105.3x45x88
Weight (g) 500
Model designation Contact load Auxiliary contact Contact configuration Coil voltage Coil termination Special code
RAVR 200 -1 12 D 1
RAVR:
Square type
020: 20A Blank: Without
auxiliary contact
-1: 1 A 12: 12VDC D: Wire lead,
without fast terminal
01~99
040: 40A 24: 24VDC E: Wire lead,
with fast terminal
100: 100A
120: 120A
150:150A
200:200A

The post RAVR200 appeared first on WRG.

]]>