君子以泽,最好看的小说排行,小说排行榜 http://exas.com.cn Thu, 11 Jun 2020 07:55:49 +0000 en-US hourly 1 http://exas.com.cn/wp-content/uploads/2023/12/cropped-WRG1176x1176-透明-32x32.png 2 Form A – WRG http://exas.com.cn 32 32 RB-2P http://exas.com.cn/en/archives/product-items/rb-2p-en Fri, 19 Oct 2018 14:03:29 +0000 http://exas.com.cn/?post_type=avada_portfolio&p=14286 ? 2 Form A/C
? Rated current: 4 to 8 A
? Small high-capability relay
? Flux-proof type
? Dielectric strength between coil & contact 5,000 V AC
? Class F coil insulation
? Control switch has enough insulation distance
? TV Load is available

The post RB-2P appeared first on WRG.

]]>

RB-2P

? 2 Form A/C
? Rated current: 4 to 8 A
? Small high-capability relay
? Flux-proof type
? Dielectric strength between coil & contact 5,000 V AC
? Class F coil insulation
? Control switch has enough insulation distance
? TV Load is available

Coil data ?
Coil input voltage 3/5/6/9/12/18/24/48 V DC
Coil power 400 mW
Response voltage < 75% (Room temp.)
Drop out voltage > 5% (Room temp.)
Operation time / Release time Less than 15 ms / less than 8 ms
Contact data ?
Contact numbers 2 Form A/C
Contact material Ag alloy
Max. switching voltage 277 V AC
Max. swiching power A Type: 2,216 VA, C Type: N.O. 2,216 VA, N.C. 1,108 VA
Contact ratings (Res. Load) A Type: 8 A 277 V AC, 1/4HP 120 V AC, TV-5 250 V AC
C Type: N.O. 8 A 277 V AC, 1/4HP 120 V AC, TV-5 250 V AC, N.C. 4 A 277 V AC N.C. 4 A 277 V AC
? ?
Contact resistence Max. 100 mΩ (1 A / 6 V DC)
Mechanical service life 1×107 times
Electrical Service life (AC1) 1×105 times
General data ?
Rated withstand impulse voltage (Coil / Contact) 5 kV AC / 1 min
Rated withstand impulse voltage (Between contacts) 1 kV AC / 1 min (same contact group), 2.5 kV AC / 1 min (different contact group)
Surge voltage 10 kV AC (1.2 / 50 μs)
Insulation Resistance 1,000 MΩ (500 V DC)
Vibration Malfunction 10~55 Hz (Amplitude1.5 mm)
? Endurance? 10~55 Hz (Amplitude1.5 mm)
Shock Malfunction 98 m/s2, Endurance 980 m/s2
Ambient temperature (Operation) -40~105 ℃ (No condensation)
Operating humidity 20~85%
Dimension L×W×H (mm) 28.9×12.6×15.7
Enclosure type Flux-proof, sealed
Mounting PCB
Weight (g) 14
Compliance certification number cULus:E345228, TUV:R50249912, CQC:CQC12002086471, VDE:40048321
Model
designation
Number
of poles
Coil
voltage
Coil
power
Contact
configuration
Contact
material
Insulation
class
Distance between
different terminals
Contact dimension
(Only for 1P)
Enclosure
type
Special
request
RB -2 12 D M * F 1 -1 -S XXX
RB 1:1 pole 03:3 V D:400 mW M:
Form A
Blank:
AgNi
Blank:
class A
1:3.5 mm(4Pins formA) 1:
Φ4.5 mm
Blank:
flux-proof
335:
2:2 poles 05:5 V Blank:
Form C
1:
AgSnO2
F:
class F
2:5.0 mm(4Pins formA) Blank:
Φ3.5 mm
S:
sealed
accordance with IEC 60335-1
06: 6 V B:
Form B
3:3.5 mm(5Pins formC)
09:9 V 4:5.0 mm(5Pins formC)
12:12 V 5:5.0 mm(6Pins formA)
18:18 V 6:5.0 mm(8Pins formC)
24:24 V 7:3.5 mm(4Pins formB)
48:48 V 8:5.0 mm(4Pins formB)
9:5.0 mm(6Pins formB)
RB Version 3.0 2 MB

The post RB-2P appeared first on WRG.

]]>
RH-2P http://exas.com.cn/en/archives/product-items/rh-2p-en Sat, 20 Oct 2018 12:06:40 +0000 http://exas.com.cn/?post_type=avada_portfolio&p=14377 ? 2 Form A
? Rated current: 25 A
? Small and high-power
? AC/DC Input voltage

The post RH-2P appeared first on WRG.

]]>

RH-2P

? 2 Form A
? Rated current: 25 A
? Small and high-power
? AC/DC Input voltage

Coil data ?
Coil input voltage 6/12/24/48/100 V DC, 12/24/50/110/220 V AC
Coil power D Type: 1,900 mW, A Type: 1.7~2.5 VA
Response voltage < 75% (Room temp.)
Drop out voltage > 5% (Room temp.)
Operation time / Release time Less than 30 ms / less than 30 ms
Contact data ?
Contact numbers 2 Form A
Contact material Ag alloy
Max. switching voltage 220 V AC
Max. swiching power 5,500 VA
Contact ratings? 25 A 220 V AC
Contact resistence Max. 50 mΩ (1 A / 6 V DC)
Mechanical service life 1×107?times
Electrical Service life (AC1) 5×104 times
General data ?
Rated withstand impulse voltage (Coil / Contact) 4 kV AC / 1 min
Rated withstand impulse voltage (Between contacts) 2 kV AC / 1 min
Surge voltage 2 kV AC / 1 min
Insulation Resistance 1,000 MΩ (500 V DC)
Vibration Malfunction 10~55 Hz (Amplitude 1.5 mm)
? Endurance? 10~55 Hz (Amplitude 1.5 mm)
Shock Malfunction 98 m/s2, Endurance 980 m/s2
Ambient temperature (Operation) -25~60 ℃ (No condensation)
Operating humidity 20~85%
Dimension L×W×H (mm) 50.5×33.5×36
Enclosure type Dust cover
Mounting PCB & faston terminal & flange type
Weight (g) 93
Compliance certification number cULus:E341569
Model designation Number of poles Coil voltage Coil type Contact configuration Terminal Shape Installation Mode Special request
RH -2 12 D M P 1 -XXX
RH 1: 1 pole DC: 6, 12, 24, 48, 100 D: DC M: Form A Blank: Faston terminal 1: Standard
2: 2 poles AC: 12, 24, 50, 110, 220 A: AC P: PCB 2: Flange
RH Version 3.0 1,014 KB

The post RH-2P appeared first on WRG.

]]>